Skip to content

DigGenRocktestGeostringDataStrMsg

Dig Gen Rocktest Geostring Data Str Msg

Roctest Geostring inclinometer integration.

Integration ID: 13 | Message Version: 0

Source Code


Field Bits Type Unit Condition Mutator Error Description
numSensors 8 UInt Always
portError 1 Bool Always
errorData 3 UInt portError == 1 EntryError(GENERAL_ERROR, 0), EntryError(GENERAL_ERROR, 1), EntryError(HARDWARE_ERROR, 2), EntryError(GENERAL_ERROR, 3), EntryError(GENERAL_ERROR, 4), EntryError(GENERAL_ERROR, 5), EntryError(GENERAL_ERROR, 6), EntryError(GENERAL_ERROR, 7)
Z Axis [numSensors] — Seq portError == 0
├── temperatureError 1 Bool —
├── temperature 3 UInt temperatureError == 1 EntryError(GENERAL_ERROR, 0), EntryError(FIELD_NOT_EXPECTED, 1), EntryError(NOT_RESPONDING, 2), EntryError(DATA_OUT_OF_RANGE, 3), EntryError(NOT_VALID, 4), EntryError(PROTOCOL_ERROR, 5), EntryError(RECEIVED_WITH_A_REPORTED_ERROR, 6), EntryError(LOW_VOLTAGE, 7)
├── temperature 11 Int Cel temperatureError == 0 ScalingMutator(×10)
├── xAxisError 1 Bool — Error flag for the X-axis. When True, xAxis holds a 3-bit error subcode; when False, it holds the value.
├── xAxis 3 UInt xAxisError == 1 EntryError(GENERAL_ERROR, 0), EntryError(FIELD_NOT_EXPECTED, 1), EntryError(NOT_RESPONDING, 2), EntryError(DATA_OUT_OF_RANGE, 3), EntryError(NOT_VALID, 4), EntryError(PROTOCOL_ERROR, 5), EntryError(RECEIVED_WITH_A_REPORTED_ERROR, 6), EntryError(LOW_VOLTAGE, 7) If the X-axis is disabled it is reported as aMeasurementError.FIELD_NOT_EXPECTED error.
├── xAxis 18 UInt mm/m xAxisError == 0 ScalingMutator(×100), OffsetMutator(+100000) X-axis slope measurement.
├── yAxisError 1 Bool — Error flag for the Y-axis. When True, xAxis holds a 3-bit error subcode; when False, it holds the value.
├── yAxis 3 UInt yAxisError == 1 EntryError(GENERAL_ERROR, 0), EntryError(FIELD_NOT_EXPECTED, 1), EntryError(NOT_RESPONDING, 2), EntryError(DATA_OUT_OF_RANGE, 3), EntryError(NOT_VALID, 4), EntryError(PROTOCOL_ERROR, 5), EntryError(RECEIVED_WITH_A_REPORTED_ERROR, 6), EntryError(LOW_VOLTAGE, 7) If the Y-axis is disabled it is reported as aMeasurementError.FIELD_NOT_EXPECTED error.
├── yAxis 18 UInt mm/m yAxisError == 0 ScalingMutator(×100), OffsetMutator(+100000) Y-axis slope measurement.
├── zAxisError 1 Bool — Error flag for the Z-axis. When True, xAxis holds a 3-bit error subcode; when False, it holds the value.
├── zAxis 3 UInt zAxisError == 1 EntryError(GENERAL_ERROR, 0), EntryError(FIELD_NOT_EXPECTED, 1), EntryError(NOT_RESPONDING, 2), EntryError(DATA_OUT_OF_RANGE, 3), EntryError(NOT_VALID, 4), EntryError(PROTOCOL_ERROR, 5), EntryError(RECEIVED_WITH_A_REPORTED_ERROR, 6), EntryError(LOW_VOLTAGE, 7) If the Z-axis is disabled it is reported as aMeasurementError.FIELD_NOT_EXPECTED error.
└── zAxis 18 UInt mm/m zAxisError == 0 ScalingMutator(×100), OffsetMutator(+100000) Z-axis slope measurement.