DigGenRocktestGeostringDataStrMsg
Dig Gen Rocktest Geostring Data Str Msg
Roctest Geostring inclinometer integration.
Integration ID: 13 | Message Version: 0
Source Code
| Field | Bits | Type | Unit | Condition | Mutator | Error | Description |
|---|---|---|---|---|---|---|---|
| numSensors | 8 | UInt | Always | ||||
| portError | 1 | Bool | Always | ||||
| errorData | 3 | UInt | portError == 1 | EntryError(GENERAL_ERROR, 0), EntryError(GENERAL_ERROR, 1), EntryError(HARDWARE_ERROR, 2), EntryError(GENERAL_ERROR, 3), EntryError(GENERAL_ERROR, 4), EntryError(GENERAL_ERROR, 5), EntryError(GENERAL_ERROR, 6), EntryError(GENERAL_ERROR, 7) | |||
| Z Axis [numSensors] | — | Seq | portError == 0 | ||||
| ├── temperatureError | 1 | Bool | — | ||||
| ├── temperature | 3 | UInt | temperatureError == 1 | EntryError(GENERAL_ERROR, 0), EntryError(FIELD_NOT_EXPECTED, 1), EntryError(NOT_RESPONDING, 2), EntryError(DATA_OUT_OF_RANGE, 3), EntryError(NOT_VALID, 4), EntryError(PROTOCOL_ERROR, 5), EntryError(RECEIVED_WITH_A_REPORTED_ERROR, 6), EntryError(LOW_VOLTAGE, 7) | |||
| ├── temperature | 11 | Int | Cel | temperatureError == 0 | ScalingMutator(×10) | ||
| ├── xAxisError | 1 | Bool | — | Error flag for the X-axis. When True, xAxis holds a 3-bit error subcode; when False, it holds the value. | |||
| ├── xAxis | 3 | UInt | xAxisError == 1 | EntryError(GENERAL_ERROR, 0), EntryError(FIELD_NOT_EXPECTED, 1), EntryError(NOT_RESPONDING, 2), EntryError(DATA_OUT_OF_RANGE, 3), EntryError(NOT_VALID, 4), EntryError(PROTOCOL_ERROR, 5), EntryError(RECEIVED_WITH_A_REPORTED_ERROR, 6), EntryError(LOW_VOLTAGE, 7) | If the X-axis is disabled it is reported as aMeasurementError.FIELD_NOT_EXPECTED error. | ||
| ├── xAxis | 18 | UInt | mm/m | xAxisError == 0 | ScalingMutator(×100), OffsetMutator(+100000) | X-axis slope measurement. | |
| ├── yAxisError | 1 | Bool | — | Error flag for the Y-axis. When True, xAxis holds a 3-bit error subcode; when False, it holds the value. | |||
| ├── yAxis | 3 | UInt | yAxisError == 1 | EntryError(GENERAL_ERROR, 0), EntryError(FIELD_NOT_EXPECTED, 1), EntryError(NOT_RESPONDING, 2), EntryError(DATA_OUT_OF_RANGE, 3), EntryError(NOT_VALID, 4), EntryError(PROTOCOL_ERROR, 5), EntryError(RECEIVED_WITH_A_REPORTED_ERROR, 6), EntryError(LOW_VOLTAGE, 7) | If the Y-axis is disabled it is reported as aMeasurementError.FIELD_NOT_EXPECTED error. | ||
| ├── yAxis | 18 | UInt | mm/m | yAxisError == 0 | ScalingMutator(×100), OffsetMutator(+100000) | Y-axis slope measurement. | |
| ├── zAxisError | 1 | Bool | — | Error flag for the Z-axis. When True, xAxis holds a 3-bit error subcode; when False, it holds the value. | |||
| ├── zAxis | 3 | UInt | zAxisError == 1 | EntryError(GENERAL_ERROR, 0), EntryError(FIELD_NOT_EXPECTED, 1), EntryError(NOT_RESPONDING, 2), EntryError(DATA_OUT_OF_RANGE, 3), EntryError(NOT_VALID, 4), EntryError(PROTOCOL_ERROR, 5), EntryError(RECEIVED_WITH_A_REPORTED_ERROR, 6), EntryError(LOW_VOLTAGE, 7) | If the Z-axis is disabled it is reported as aMeasurementError.FIELD_NOT_EXPECTED error. | ||
| └── zAxis | 18 | UInt | mm/m | zAxisError == 0 | ScalingMutator(×100), OffsetMutator(+100000) | Z-axis slope measurement. |