Skip to content

DigGmmInstructionsPort0CfgStrMsg

Dig Gmm Instructions Port 0 Cfg Str Msg

AM Type: 151

Source Code


Field Bits Type Unit Condition Validator Description
ls_header — Struct Always
├── uplink_version 4 UInt Always
├── node_id_high 4 Fragment Always
├── product_code 8 UInt Always
├── node_id 16 UInt Always
├── sequence_number 8 UInt Always
└── am_type 8 UInt Always
configVersion 8 UInt Always ValueValidator(0)
rfu 4 Reserved Always
configId 12 UInt Always RangeValidator[0, 68] Supported configs can be seen in the generic_modbus_configs.json file
swapModbusWordSensorEndianness 8 UInt Always Word swap control for sensor Modbus values: 0 = no word swap; any non-zero value = perform word swap.
sensorReadingTimeout 24 UInt ms Always RangeValidator[1, 1677721]
globalNumberOfInstructions 8 UInt Always
globalInstructionBuffer 120 Bytes Always See Annex G instruction format.
sensorNumberOfInstructions 8 UInt Always
sensorInstructionsBuffer 3200 Bytes Always See Annex G instruction format.